Outdoor Lighting Glossary
Twenty-three terms used in facade and landscape specifications. Each entry gives the definition first, then what it changes on a real installation.
Specification disputes often start with a term carrying two meanings: an IP rating read as a whole-family guarantee, a beam angle treated as a photometric file, or a pixel pitch treated as a maximum string length. These definitions state what each term means and what it does not mean, using figures from the 2026 catalogues where relevant.
A
- Addressing
-
The assignment of a unique DMX start address to each fixture or pixel so the controller can command it separately.
An RGBW fixture starting at address 5 occupies addresses 5 to 8. Overlapping start addresses make two fixtures respond to the same command, which is the usual cause of an effect that looks correct in simulation but wrong on the wall.
B
- Beam angle
-
The angular width of the emitted light cone, measured between the directions where intensity falls to a specified fraction of the peak.
GD-WW2430 is listed with 30°, 60°, 10 × 30° and 10 × 60° options. A 10 × 30° distribution covers a different wall area than a 60° cone at the same distance, so spacing follows the photometric file, not the label.
- Binary vs RGBW control
-
Binary control switches channels on and off, while RGBW control sets an intensity level independently for each of four colour channels.
A binary scheme on the 27-model point-source range cannot produce the tint changes an RGBW scheme can. Confirm protocol and channel map per model before writing an effect schedule; the two schemes are not interchangeable by firmware alone.
C
- CCT — Correlated Colour Temperature
-
The colour appearance of white light expressed in kelvin, where a lower value looks warmer and a higher value looks cooler.
Single-colour versions are quoted per model, not as one site-wide value. Mixing two CCT bins on the same elevation without a documented schedule produces visible patches, so confirm the ordered CCT per fixture.
- CRI — Colour Rendering Index
-
A measure, on a scale up to 100, of how faithfully a light source renders object colours compared with a reference source.
A high CRI value does not guarantee that two batches look the same. For a colour-critical façade, confirm CCT consistency and binning together with CRI, because the visible difference usually comes from the bin rather than the index.
- Corrosion resistance
-
The ability of a material or finish to resist degradation when exposed to moisture, salt or chemicals.
GDXC lists die-cast aluminium, 6063 extruded aluminium, tempered / silk-screened glass and PC as materials. A coastal or chemical site needs a finish decision per project; an IP number alone says nothing about corrosion behaviour.
D
- DMX512
-
A digital control protocol for architectural and stage lighting that carries 512 control channels on one data link, called a universe.
An RGBW fixture using four channels occupies four of the 512 addresses, so a 128-fixture RGBW run fills one universe. Universe planning starts from the channel map per model, not from the fixture count alone.
- Daisy chain
-
A wiring layout in which each fixture connects to the next one along the same power or signal run.
On a DC24V chain, voltage falls along the cable as more fixtures are added. Confirm run length and cable size from the project layout instead of assuming a catalogue string count is valid on site.
F
- Façade grazing
-
A lighting technique in which light is aimed steeply across a textured wall so surface relief is revealed by shadows.
The 2026-11-09 enquiry showed textured lower wall areas on a 70 × 50 ft elevation. Grazing angle and stand-off distance need a mock-up: the same fixture at a different offset reads as a flat wash instead of visible texture.
G
- Glare / UGR — Unified Glare Rating
-
UGR is a numeric index for discomfort glare from luminaires in indoor work spaces; outdoor façade work more often uses shielding angle and luminance at the observer.
A wall washer aimed up a façade can still shine into a road or a neighbouring window. Check the aiming angle and the shielding on the installed fixture rather than importing an indoor UGR target into an outdoor specification.
I
- IP rating — Ingress Protection rating
-
A two-digit classification that states how well an enclosure resists solid particles and water, where the second digit covers liquid ingress.
The 2026 catalogues list GD-WW3524 and GD-WW6036 at IP65, and GD-WW2418 and GD-WW2430 as IP67 potted constructions. A catalogue rating describes the housing only; field joints and cable glands are specified separately, and one rating does not cover every model in the family.
- In-ground luminaire
-
A luminaire installed flush with a walkway or planting surface, with a sealed housing designed to sit in a wet environment.
GD-IG225 is Ø150 × 145 mm with a Ø143 × 145 mm cut-out and 3 W–6 W variants; confirm the configuration before the opening is cast. The IP67 rating is a catalogue specification; the test report is supplied per configuration on request.
L
- Lumen maintenance
-
The share of initial light output that a LED source still produces after a stated number of operating hours.
Rated lifetime is a catalogue field that must be read against the exact configuration and test basis. It is not a warranty promise; the published warranty is 3 years.
- Light pollution
-
Unwanted or excessive artificial light that spills beyond the area intended to be lit.
On a façade, upward spill and glare into neighbouring windows are controlled by aiming and shielding. A 10 × 30° option limits vertical spread compared with a 60° cone, subject to the photometric file for that configuration.
P
- Pixel pitch
-
The centre-to-centre distance between adjacent addressable light points in a linear run or matrix.
The GDXC catalogue describes 160 mm spacing and 30 pixels per string for point sources. Those are catalogue descriptions, not a maximum string length for a site; run length is checked against the installed cable and driver layout.
- Photometric file / IES — IES LM-63 file
-
A standardised data file that describes a luminaire’s light distribution for use in lighting design software.
GDXC supplies photometric / IES files per configuration on request. A beam-angle label in a catalogue is not enough to calculate spacing or overlap; the file must match the chosen beam option and colour version.
R
- RDM — Remote Device Management
-
A bidirectional extension of DMX512 that lets a controller discover fixtures, read status and change addresses over the same data link.
Without RDM, changing an address normally means reaching each fixture physically. Confirm RDM support per model before designing a scheme that depends on remote addressing and fault reporting.
- RGBW
-
A four-channel colour mixture using red, green, blue and white emitters, where the white channel raises output and improves neutral whites.
Each RGBW fixture consumes four DMX channels: a 128-fixture run needs 512 channels, or one universe. Channel count, not fixture count, determines how many controllers and data runs a project needs.
- Rotating bracket
-
A mounting bracket that allows the luminaire body to be aimed after it is fixed to the building.
GD-WW2430 is offered with rotating or flat brackets. The 985 mm profile length and the bracket swing both have to be checked against the elevation before anchors are set; the bracket choice changes the achievable aiming range.
S
- Seal / gland — Cable gland
-
A fitting that secures a cable where it enters a luminaire while preserving the enclosure’s resistance to water and dust.
IP67 potted constructions such as GD-WW2418 and GD-WW2430 seal the housing internally. The gland and connector still have to be checked against the installed cable diameter, or the enclosure rating is lost at the entry point.
T
- Thermal resistance
-
The temperature rise per watt of heat flowing from the LED junction through the housing to the surrounding air, expressed in °C/W.
A 48 W fixture moves four times the heat of a 12 W model, so housing mass and contact with the mounting surface matter as much as the driver rating. Die-cast aluminium and 6063 extrusion are listed housing materials; thermal behaviour is confirmed per model.
V
- Voltage drop
-
The reduction in voltage along a cable caused by cable resistance and the current drawn by the connected fixtures.
On a long DC24V run, the last fixture can receive less voltage than the first, so brightness varies along the line. Calculate per run length and cable size; a catalogue pixel count does not settle the question.
W
- Wall washer
-
A luminaire designed to spread light across a vertical surface with usable uniformity, usually mounted at a stand-off distance from that surface.
GDXC catalogues 20 wall-washer model entries in 2026; GD-WW2430 is 24 × 30 × 995 mm with 12 W / 15 W versions on DC24V. The catalogue entry defines the fixture, not the spacing on your elevation.
Definitions follow common industry usage for ingress-protection codes and DMX512 control. Where a catalogue uses a term differently, the practical consequence is stated in the detail paragraph. A definition does not replace a per-model document.