Fundamentals

IP Ratings for Outdoor LED Fixtures

IP65 and IP67 describe outdoor LED fixture enclosures, not field joints. GDXC wall washers and in-ground lights listed by model, with selection limits.

GDXC Lighting · Published November 25, 2026 · Updated November 29, 2026 · 6 min read

Short answer

An IP rating is a two-digit enclosure code under IEC 60529: the first digit rates solid-particle ingress, the second water. GDXC Lighting lists IP65 wall washers (GD-WW3524, GD-WW6036), a glue-filled IP67 version (GD-WW2418) and IP67 in-ground bodies (GD-IG225, GD-IG226). The code describes the fixture enclosure; field cable joints and drainage are specified separately.

Key points

  • The first IP digit covers solids; the second covers water. IP65 and IP67 differ only in the second digit.
  • The catalogue lists IP65 on GD-WW3524 and GD-WW6036, IP67 glue-filled on GD-WW2418, and IP67 in-ground bodies on GD-IG225 and GD-IG226.
  • An enclosure code does not cover a cable joint made on site or water standing in a recess.
  • Every GDXC outdoor fixture carries a 3-year warranty; the rating is a catalogue specification, not a tested lifetime.

Definition

An IP rating, or Ingress Protection code, is a two-digit classification defined in IEC 60529 that states how well an enclosure resists solid particles and water. The first digit runs from 0 to 6 and describes protection against solids; the second runs from 0 to 9 and describes protection against water. The code is a description of an enclosure, not a performance guarantee and not a statement about how a product is installed.

For facade specifiers, the practical value is narrow but useful: it lets two fixture bodies be compared on the same scale. GD-WW3524 and GD-WW6036 are listed at IP65; GD-WW2418 is listed as IP67 with a glue-filled seal. The in-ground models GD-IG225 and GD-IG226 are listed at IP67. Those are catalogue figures tied to named models, and they should be read that way.

Decoding the two digits

The number is read digit by digit, not as a score. A higher second digit does not make a fixture better in every situation; it describes a different water exposure.

DigitPositionMeaning in plain termsRelevance here
6FirstDust-tight; no solid particle ingressCommon to the IP65 and IP67 fixtures listed below
5SecondProtected against water jets from any directionListed on GD-WW3524 and GD-WW6036
7SecondProtection against temporary immersion in waterListed on GD-WW2418, GD-IG225 and GD-IG226
—NeitherNo rating for drive-over load, impact or chemical exposureLoad class and IK are separate specifications

The table is why an IP code cannot be used on its own to approve a fixture. A wall washer at IP65 and an in-ground light at IP67 share the same dust-tight first digit; the difference is how much water the enclosure tolerates. Neither digit says anything about a vehicle driving over the in-ground lens, which is a separate load question.

What the catalogue actually lists

The GDXC 2026 catalogues cover 11 product families and 98 model entries. Within them, the ingress figures are attached to specific models rather than applied across a family. The IP sealing capability records the construction behind each figure.

ModelFamilyListed enclosureRelevant body figure
GD-WW3524Wall washerIP65W35 × H24 × L1002 mm; 18W/24W, DC24V
GD-WW6036Wall washerIP65W60 × H36 × L1000 mm; 48W/72W, DC24V
GD-WW2418Wall washerIP67, glue-filledW24 × H18 × L995 mm; 12W/15W, DC24V
GD-IG225In-groundIP67 per catalogueØ150 × 145 mm; cut-out Ø143 × 145 mm; 3W/6W
GD-IG226In-groundIP67 per catalogueØ180 × 158 mm; 6W/9W/9×2W

Two entries deserve a note. GD-L2048PC, the W20 × H48 × L1000 mm linear bar at 10W/12W/15W, has no ingress figure in the available catalogue extract, so no IP code is quoted for it. GD-IG225 is confirmed at 3W / 6W. Both points come from the model record.

The field joint boundary

The most common misreading of an IP code is to treat it as a property of the whole installation. It is not. The enclosure of GD-WW2418 may be glue-filled to IP67, but a connector joined in the field at 2 a.m. on a scaffold is a different object with a different rating. The same applies to the cable gland, the junction box and the sleeve around a buried in-ground body.

This distinction drives specification work: on a wall washer run, connector position, cable entry direction and drip loop are drawn before the fixture count is fixed. On an in-ground fixture, the recess is reviewed for groundwater, irrigation and runoff: a Ø143 × 145 mm cut-out for GD-IG225 means a sleeve and a drainage path. The in-ground selection article works through that sequence.

Selecting by exposure, not by number

A workable selection order starts with where the fixture sits, then reads the enclosure code.

ExposureFirst questionListed answerWhat remains open
Covered facade, occasional rainIs a dust-tight, jet-protected body enough?GD-WW3524 or GD-WW6036 at IP65Connector position and gland detail
Exposed facade, wind-driven rainIs a glue-filled body needed?GD-WW2418 at IP67Mounting plane and cable entry direction
Ground level, planting or pavingCan the recess drain?GD-IG225 or GD-IG226 at IP67Cut-out, sleeve, buried joint and load class
Near water or submergedIs the enclosure rated for that condition?Not covered by the listed outdoor familiesA dedicated underwater housing is required

The last row is a real boundary. The IP codes discussed here describe outdoor-air fixtures. They do not qualify a fixture for a pool edge, a fountain or a walk-over surface. Applying an IP65 wall washer to a submersible position is a category error, not a conservative choice.

Warranty, documents and what the code does not say

GDXC Lighting applies a 3-year warranty across every outdoor fixture line and has delivered 300+ lighting engineering projects since 2014. GDXC products comply with CE requirements; no certificate number is published on this site. The warranty covers the fixture as supplied against its agreed configuration; it does not rate a site joint or state a service life.

Rated-life figures are catalogue statements, not tested lifetimes or warranty terms; verify them per configuration. In the same way, an IP figure is a catalogue specification for an enclosure. It should be recorded in a schedule as such, with the joint, gland and drainage details recorded beside it rather than hidden under the same code.

Scope and limits

This article covers enclosure ratings for outdoor-air architectural fixtures in the listed families. It does not cover submersible housings, drive-over load classes, impact ratings or the electrical protection of a circuit. No certificate number is published here. Where a figure is not present in the catalogue extract — as with GD-L2048PC — this article leaves it unstated rather than inferring one from a similar model.

Selection sequence

  1. Classify the exposure: covered, wind-driven rain, ground level, or near water.
  2. Read the listed enclosure code for one named model, not for a whole family.
  3. Check the body figure that goes with it — length, power and cut-out — before counting fixtures.
  4. Specify the connector, gland and drainage as separate items.
  5. Mark anything absent from the catalogue as open, and confirm it against the exact configuration.

For the wider order process, see the facade lighting buyer checklist and the wall washer definition.

This article describes general outdoor lighting practice and catalogue figures. It is not a substitute for a configuration-specific review — beam option, IP construction, mounting conditions and per-model documents depend on the exact fixture.

Questions

Frequently asked

What does IP65 mean for outdoor LED lights?

Under the IP rating system, the 6 means dust-tight and the 5 means protection against water jets from any direction. In the GDXC catalogue, GD-WW3524 and GD-WW6036 are listed at IP65. The code applies to the fixture enclosure, not to a cable joint or connector installed on site.

Is IP65 or IP67 better for a facade wall washer?

IP67 adds temporary immersion protection to the same dust-tight first digit. GDXC lists GD-WW3524 and GD-WW6036 at IP65, and GD-WW2418 as an IP67 glue-filled construction. The choice follows exposure and mounting detail, not a blanket preference for the higher number.

Does an IP67 rating cover the cable joint?

No. The code rates the fixture enclosure. A buried or exposed joint is a separate part of the installation and is specified with its own connector, gland and drainage detail. That interface is the subject of the failure-analysis article.

Can IP67 in-ground lights be installed where water collects?

The body of GD-IG225 or GD-IG226 may carry an IP67 code, but standing water in the recess is a drainage problem the enclosure rating does not solve. The cut-out, sleeve and runoff path are reviewed before the fixture is selected.

Send your elevation, get a project quote

Send the facade drawing or fixture schedule with quantity and destination. Quotes are built per configuration and trade terms; no internal price list is published.

Chat on WhatsApp