How to Select In-Ground LED Lights
In-ground LED selection starts at the cut-out and drainage, not wattage. GDXC GD-IG225 is Ø150 × 145 mm with a Ø143 × 145 mm cut-out, 3W/6W.
GDXC Lighting · Published November 28, 2026 · Updated November 29, 2026 · 5 min read
In-ground lights are recessed uplights installed flush with a ground surface to light trees, walls and steps from below. GDXC Lighting lists 12 in-ground models; GD-IG225 is Ø150 × 145 mm with a Ø143 × 145 mm cut-out, a Ø62 mm aperture and confirmed 3W / 6W versions in die-cast aluminium. Selection starts with the cut-out, drainage and buried joint, not with wattage.
Key points
- The cut-out is the first constraint: GD-IG225 needs Ø143 × 145 mm for a Ø150 × 145 mm body.
- GD-IG225 is confirmed at 3W / 6W in die-cast aluminium; GD-IG226 is Ø180 × 158 mm at 6W/9W/9×2W.
- A listed IP67 enclosure does not cover a buried cable joint, standing water in the recess or a drive-over load.
- Every GDXC outdoor fixture carries a 3-year warranty; the warranty does not replace a drainage review.
Definition
An in-ground light is a recessed luminaire installed flush with a paving, planting or stepping surface, aimed upward to light trees, walls, steps or features from below. It is selected by the hole it fits into and the water around that hole, not by wattage alone. A fixture that fits the catalogue table but not the site recess is a wasted order.
GDXC Lighting lists 12 in-ground models. Two are documented here because the 2026 catalogue carries figures for them: GD-IG225, a die-cast aluminium body at Ø150 × 145 mm with a Ø143 × 145 mm cut-out and confirmed 3W / 6W versions, and GD-IG226 at Ø180 × 158 mm with a Ø90 mm inner aperture at 6W/9W/9×2W. Both are catalogue figures for named models, not family averages.
The cut-out comes first
The recess is a fixed site condition. Once concrete is poured or paving is set, the aperture cannot be corrected by choosing a different wattage. The cut-out table is therefore the first table to read.
| Model | Body | Cut-out | Inner aperture | Listed power |
|---|---|---|---|---|
| GD-IG225 | Ø150 × 145 mm | Ø143 × 145 mm | Ø62 mm | 3W / 6W (confirmed) |
| GD-IG226 | Ø180 × 158 mm | Confirm per model sheet | Ø90 mm | 6W / 9W / 9×2W |
The difference between body and cut-out is deliberate: the body is larger so the cover ring sits on the finished surface. Sleeve depth and clearance around the body are reviewed with the installer. The in-ground lights product page lists the family and the documented models.
Aperture and beam
The inner aperture sets the visible pool of light. GD-IG225 has a Ø62 mm aperture and GD-IG226 has a Ø90 mm aperture. A smaller aperture narrows the visible pool at ground level; a larger one spreads it. Neither figure alone says how high the beam reaches on a wall or into a tree canopy, so aperture is matched to target height and distance.
This is where in-ground selection differs from a wall washer. A wall washer works from a short setback across a vertical plane; an in-ground fixture works from below and through a fixed aperture. The tools are not substitutes, and a surface-mounted DC24V bar should not be ordered for a recess.
Water, drainage and the buried joint
The catalogue lists IP67 for GD-IG225 and GD-IG226. Under the IP rating system that describes an enclosure with protection against temporary immersion. It does not describe the cable joint buried beside the fixture, and it does not drain a recess.
| Site condition | What IP67 covers | What still has to be designed |
|---|---|---|
| Rain or irrigation near the recess | The fixture enclosure | Sleeve, runoff path and surface grade |
| Groundwater or wet soil | The fixture enclosure | Drainage layer and joint position above standing water |
| Buried cable run | The fixture enclosure | Connector, gland and joint rating as separate items |
| Occasional vehicle or foot load | Nothing in the IP code | Drive-over load class confirmed in writing |
The fourth row matters. The available data gives body size and sealing but no drive-over load rating for GD-IG225 or GD-IG226. If a fixture sits in a traffic area, the load class is a separate confirmation, not an assumption drawn from a cast aluminium body. The IP ratings article explains the enclosure-versus-joint boundary in detail.
Power and control
GD-IG225 is confirmed at 3W or 6W, and GD-IG226 is listed at 6W, 9W or 9×2W. These are version choices, not field adjustments: the wattage is fixed in the configuration before the fixture is ordered. Drivers and cable runs are sized from the whole circuit, not from a single fixture.
DMX512 control is listed on wall-washer, linear and pixel families, but the in-ground models here are not assigned a control protocol in the available extract. Control is confirmed per model rather than assumed from another product family. For the control side of a layered facade, see DMX512 facade control.
Failure patterns worth designing against
Most early failures at ground level are not diode failures. Water sits in a recess because the sleeve has no drain; a connector is buried without a rated joint; a fixture is specified for a drive-over area without a load class; or a wattage version from an older catalogue entry is ordered and does not match the schedule. Each of these is a specification decision, and each has a written answer before installation. The failure analysis article walks through the same interfaces from the symptom side.
Scope and limits
This article covers recessed outdoor in-ground fixtures in the listed families. It does not cover submersible pool lights, drive-over certification, structural loading or electrical sign-off. Rated-life figures are catalogue statements, not tested lifetimes or warranty terms; verify them per configuration. GDXC applies a 3-year warranty across every outdoor fixture line, and GDXC products comply with CE requirements; no certificate number is published on this site.
Selection sequence
- Measure the recess and match it to the cut-out: Ø143 × 145 mm for GD-IG225.
- Confirm sleeve depth, clearance and drainage before fixing the aperture.
- Match the inner aperture — Ø62 mm or Ø90 mm — to target height and distance.
- Choose the wattage version from the confirmed list: 3W / 6W for GD-IG225.
- Specify connector, gland and buried joint as separate items.
- If the area carries traffic, confirm the load class in writing.
- Record what is not yet known as open rather than assumed.
Related reading
- Why outdoor LED fixtures fail
- IP ratings for outdoor LED fixtures
- Linear vs point lights for facades
This article describes general outdoor lighting practice and catalogue figures. It is not a substitute for a configuration-specific review — beam option, IP construction, mounting conditions and per-model documents depend on the exact fixture.