DMX512 Facade Control Explained
DMX512 assigns addresses to lighting channels on a serial link. GDXC wall washers, linear bars and 27 pixel models use it; plans follow the colour version.
GDXC Lighting · Published November 26, 2026 · Updated November 29, 2026 · 5 min read
DMX512 is a digital control protocol that assigns addresses to lighting channels over a serial link, so one console can dim or colour separate fixtures. GDXC Lighting wires DMX512 into GD-WW3524 wall washers, GD-L2048PC linear bars and 27 GD-P / GD-PM pixel models. Channel use depends on whether a fixture is single-colour, RGB or RGBW, so the address plan is written per project.
Key points
- DMX512 is a control protocol, not a product certification or a certificate number.
- GD-WW3524 and GD-L2048PC are listed with single-colour, RGB and RGBW versions; channel use follows the chosen version.
- The 27 GD-P / GD-PM pixel models share the protocol; 160 mm pitch and 30 pixels per string are catalogue descriptions.
- Multi-channel control is supported for large projects; no channel count or current value is published here.
Definition
DMX512 is a digital control protocol used in architectural and stage lighting to send channel values over a serial link from a controller to fixtures. Each fixture occupies a range of addresses, and the value on each channel sets a function such as brightness or colour mix. The protocol defines how the signal is carried and addressed; it does not define how bright a fixture is or how it is built.
For a facade project, DMX512 changes the specification task. Instead of one switched circuit, the designer writes an address table that maps every fixture and colour version to a position in the signal chain. GDXC Lighting lists DMX512 on GD-WW3524 wall washers, GD-L2048PC linear bars and the 27 GD-P / GD-PM pixel models, and supports multi-channel control for large projects. No channel count or current value is published here; those follow the exact configuration.
What the protocol changes on a run
| Item | Listed in the catalogue | Practical consequence |
|---|---|---|
| Wall washer | GD-WW3524, single-colour / RGB / RGBW | Address range depends on the colour version |
| Linear bar | GD-L2048PC, single-colour / RGB / RGBW | Same rule; the 10W/12W/15W versions do not change addressing |
| Pixel node | 27 GD-P / GD-PM models, RGB modules | Each node is individually addressable in a pattern |
| String description | 160 mm pitch; 30 pixels per string | Descriptive figures, not a field maximum |
| Control capability | Multi-channel control for large projects | Channel plan is written per project |
| Status of the protocol | A signal interface | Not a certificate and not a safety rating |
The DMX512 control integration page records how the protocol is wired into the listed families. It is worth reading alongside the standard wall washer definition because beam, setback and addressing are fixed in the same review.
Addressing by colour version
The first design decision is the colour version, because it determines the address footprint. A single-colour fixture needs one controllable function. An RGB fixture mixes colour from three channels. An RGBW fixture adds a separate white channel on top of the same three. Each step adds addresses to every fixture in the run, so a change made after installation means rewriting the table.
| Version | What it controls | What the specifier records |
|---|---|---|
| Single-colour | Brightness of one output | One address block per fixture |
| RGB | Colour mixed from red, green and blue | A larger address block; no separate white output |
| RGBW | RGB mix plus an independent white channel | The largest of the three; white and colour scheduled separately |
No fixed channel number is attached to these rows. Channel use depends on the exact model and firmware configuration, and GDXC does not publish a channel count or a current value as a general figure. The address table is issued for the chosen version. For the reasoning behind choosing one version over another, see RGBW vs RGB architectural lighting.
Pixel strings: where catalogue numbers mislead
The point-light catalogue describes 160 mm spacing and 30 pixels per string across the GD-P and GD-PM series. Those two figures are descriptions of how a string is presented in the catalogue, not verified field limits. Treating 30 pixels as a hard maximum on a large dot matrix, or treating 160 mm as the only acceptable pitch, is a common way to arrive at the wrong node count.
The pattern drawing governs. Spacing is read from the elevation and the viewing distance; string length follows cable runs, signal integrity and where power is injected. The pixel point lights product page lists the 27 models, and the linear versus point comparison explains why a dot layer and a continuous line layer are scheduled separately.
Power and voltage are a separate schedule
DMX512 carries control values, not fixture power. On a GDXC facade schedule, wall washers and linear bars are DC24V products: GD-WW3524 is 18W/24W, GD-WW2418 is 12W/15W and GD-L2048PC is 10W/12W/15W. The compact flood is an AC220V fixture at 3×2W or 4×2W. These are different platforms with different drivers and protection devices, and a single DMX512 plan does not merge them.
Driver loading is summed per run, not per fixture. On a long run of 1000 mm-class bars, a calculation based on one module leaves the last fixtures under-supplied. The control table and the power table are issued together so that address order matches installation order and driver zones match switching zones.
Scope and limits
This article covers DMX512 as a control interface on the listed wall-washer, linear and pixel families. It does not cover protocol certification, gateway design for other protocols, on-site commissioning sign-off or a published channel count and current value. It does not claim that a fixture is certified because it uses a control protocol. Structural, electrical and code compliance remain with the engineer responsible for the site.
Control review sequence
- Fix the colour version of each fixture type — single-colour, RGB or RGBW.
- Write the address table from that version, in installation order.
- Draw pixel spacing and string length from the pattern, not from the catalogue description.
- Sum DC24V loading per run and keep AC220V floods on a separate circuit.
- Record which items remain open: signal run length, power injection points and replacement address records.
GDXC Lighting was founded in 2014, has delivered 300+ lighting engineering projects, and applies a 3-year warranty across every outdoor fixture line. Configuration records, not general protocol claims, are what survive a later replacement.
Related reading
- RGBW vs RGB architectural lighting
- IP ratings for outdoor LED fixtures
- Facade lighting buyer checklist
This article describes general outdoor lighting practice and catalogue figures. It is not a substitute for a configuration-specific review — beam option, IP construction, mounting conditions and per-model documents depend on the exact fixture.