IP Sealing Constructions for Outdoor LED Fixtures
Fixture-level IP65 and IP67 constructions: GD-WW3524 and GD-WW6036 at IP65, GD-WW2418 glue-filled IP67, and IP67 in-ground models GD-IG225 and GD-IG226.
IP sealing is the enclosure construction that limits dust and water ingress, written as a two-digit code under the IP rating system. GDXC Lighting builds IP65 wall washers (GD-WW3524, GD-WW6036), a glue-filled IP67 version (GD-WW2418) and IP67 in-ground housings (GD-IG225, GD-IG226). The rating applies to the fixture body, not to field joints.
When this process applies
This page covers enclosure construction for outdoor air fixtures. It does not cover submersible use, drive-over load classes or buried cable joints; those are specified separately from the fixture IP code.
Technical specifications
| IP65 fixtures | GD-WW3524, GD-WW6036 |
|---|---|
| IP67 glue-filled | GD-WW2418 |
| IP67 in-ground | GD-IG225, GD-IG226 |
| GD-WW3524 lens | 4 mm silk-screened glass |
| In-ground bodies | Ø150 × 145 mm and Ø180 × 158 mm, cast aluminium |
| Field joints | Specified separately; not covered by the fixture IP code |
| Product details | Confirmed per model; no certificate number published here |
Where it is the right choice
- Exposed facade bars where IP65 construction is specified
- Wall washers with higher water exposure using the IP67 glue-filled version
- Recessed ground-level fixtures with drainage designed around the body
- Landscape zones where connectors are reviewed with the installation
Where it is the wrong choice
Stating this explicitly matters more than a capability list: if your part falls into one of these categories, another process will cost you less.
- Submersible pool installations — use a dedicated underwater family
- Drive-over areas without a separately confirmed load class
- Assuming an IP67 fixture makes a buried cable joint IP67
Equipment
- Glue-filled sealing construction for GD-WW2418
- Sealed connectors at the fixture cable entry
- Stainless steel cover rings on the in-ground series
- Seal and connector inspection as a build step before packing
- Per-model documentation available on request
Process questions
What is the difference between IP65 and IP67 wall washers?
Under the IP rating system, IP65 protects against dust and water jets; IP67 adds temporary immersion protection. In the catalogue, GD-WW3524 and GD-WW6036 are IP65, while GD-WW2418 uses an IP67 glue-filled seal. The code describes the fixture enclosure, not the site joint.
Are IP67 in-ground lights safe to bury?
The bodies of GD-IG225 and GD-IG226 are listed at IP67, but burial also involves a cable joint and local drainage. Those are designed separately: GD-IG225 needs a Ø143 × 145 mm cut-out, and standing water in the recess is a design issue the IP code does not solve.
How is water protection specified for an outdoor fixture?
Catalogue ratings such as IP65 and IP67 describe the housing construction only. Field joints and cable glands are specified for the installation, and this site publishes no certificate numbers.
Related capabilities and products
Thermal Management
Thermal management in LED luminaires is the housing and board path that moves junction heat into the surrounding air. GDXC Lighting builds fixture bodies from 6063 extruded aluminium and cast aluminium, with listed models from 10W to 72W: GD-WW3524 is 18W/24W in a W35 × H24 body, while GD-WW6036 is 48W/72W in W60 × H36..
View capabilityDMX512 Control Integration
DMX512 is a digital control protocol used to address lighting channels across a serial link. GDXC Lighting wires DMX512 into GD-WW3524 wall washers and GD-L2048PC linear bars, and lists 27 GD-P / GD-PM pixel models using the same protocol.
View capabilityCustom Project Engineering
Custom project engineering is the selection and layout work that turns an elevation and fixture schedule into an orderable configuration. GDXC Lighting works across 11 product families and 98 catalogued models, covering DC24V facade bars and AC220V floods; one 2026 design-review inquiry used a 70 × 50 ft front elevation.
View capabilityKnowledge Base
Beam, IP and control notes with model-level figures and stated limits, written for buyers.
Read articlesSend your elevation, get a project quote
Send the facade drawing or fixture schedule with quantity and destination. Quotes are built per configuration and trade terms; no internal price list is published.