LED Flood Lights for Architectural and Area Lighting
Directional LED flood lights for facades and areas: 29 catalogued models. Compact body 65 × 65 × 55 mm, 3×2W or 4×2W, AC220V input.
Flood lights are directional LED fixtures that project a concentrated beam onto a surface or an area from a distance. GDXC Lighting catalogues 29 flood models; the compact square body measures 65 × 65 × 55 mm and uses 3×2W or 4×2W LED arrays on AC220V, while project-series names such as FL-BM and FL-FG are listed without fixed wattages in current material.
Scope: what this product page covers
This page covers directional flood fixtures for building, area and landscape lighting. It does not cover DC24V facade bars or in-ground uplights. Wattages are quoted only where the current catalogue states them; project-series models are confirmed by model sheet.
Specifications
| Catalogued flood models | 29 entries in the 2026 catalogue |
|---|---|
| Compact square body | 65 × 65 × 55 mm |
| Compact LED array | 3×2W or 4×2W |
| Compact input | AC220V |
| Project series names | FL-BM, FL-FG (no wattage published in current material) |
| Historical series names | FL-YG / YX / WT (names only) |
| Beam specification | Confirm per model; no single beam angle assigned to the compact body |
Materials
- Cast aluminium body where specified
- Tempered glass front lens
- Aluminium aiming bracket or yoke
- Sealed cable gland and connector parts
Manufacturing process
- Throw and aim calculation The mounting point, target surface and throw distance are fixed first. Floodlights are aimed, not washed, so an incorrect mounting position cannot be corrected by changing the diffuser.
- Beam and array selection A beam option is selected per model. The compact body is listed with 3×2W or 4×2W arrays only; no beam angle is assigned to it in the available material, so the model sheet governs.
- Body and sealing configuration Body material, front lens and cable entry are fixed together. The compact 65 × 65 × 55 mm fixture is an AC220V product, so its circuit is separate from DC24V facade runs.
- Electrical protection design AC220V circuits are grouped by switching zone and protection device. The aim plan and circuit list are issued together so that one floodlight is not left on a different zone from its neighbour.
- Pre-dispatch aim and power check Each fixture is checked for wattage version, connector condition and label. The packing record states the model and array so the installer does not infer wattage from the body size.
Flood Lights in production
Typical applications
- Facade and signage illumination from a distance
- Building entrance and canopy lighting
- Landscape trees and feature structures
- Wall and column highlighting
- Large-area security and amenity lighting
Quality and documentation
- 3-year warranty on every outdoor fixture
- Wattage array and model label verified against the fixture schedule
- Connector and cable gland checked on each assembly
- Aim bracket and fastener fit checked before packing
- Photometric data supplied per selected model on request
- Per-model documentation available on request
What we do not do
We do not assign the FL-BM or FL-FG series a wattage or lumen figure because current material does not publish one; request the model sheet before specifying. The compact 65 × 65 × 55 mm body is an AC220V fixture, not a DC24V facade module, so it does not share drivers with wall washers or linear lights.
Technical questions
What wattage is the compact square LED floodlight?
The compact 65 × 65 × 55 mm body is listed with 3×2W or 4×2W LED arrays on AC220V. Larger project-series names such as FL-BM and FL-FG appear in older material without wattages, so we do not publish a figure for them; request the current model sheet.
Can a 65 mm floodlight light a 30 m facade?
A compact 65 × 65 × 55 mm fixture with a 3×2W or 4×2W array is not sized for a 30 m throw on its own. Throw distance, aim angle and fixture count are calculated together from the elevation; larger project-series models are reviewed by model sheet rather than by body size.
Are flood lights DMX512 controllable?
The available catalogue extract assigns DMX512 to wall-washer and linear models, but not a control protocol to the compact flood body. Control is confirmed per flood model; do not assume a DC24V facade address plan applies to an AC220V floodlight.
What does IP65 mean for an outdoor flood light?
Under the IP rating system, IP65 describes a dust-tight fixture with protection against water jets. It applies to the fixture enclosure, not to a field cable joint. Sealing construction is confirmed per model, and per-model documentation is available on request.
Adjacent products and capabilities
Wall Washer Lights
Wall washer lights are linear LED fixtures mounted parallel to a facade to throw an even wash of light across vertical surfaces from a short setback. GDXC Lighting catalogues 20 wall-washer models, including GD-WW3524 at 18W/24W with 30°, 60°, 10×30° and 10×60° beam options, DC24V input and IP65 construction..
View productPixel Point Lights
Pixel point lights are individually addressable LED nodes spaced along a cable to form dots, matrices or animated facade patterns. GDXC Lighting lists 27 point-light models in the GD-P and GD-PM series; the catalogue describes 160 mm spacing and 30 pixels per string, and pixels are controlled over DMX512.
View productIn-Ground Lights
In-ground lights are recessed uplights installed flush with a walking or landscaping surface to light trees, walls and steps from below. GDXC Lighting lists 12 in-ground models; GD-IG225 is Ø150 × 145 mm with a Ø143 × 145 mm cut-out, die-cast aluminium housing and confirmed 3W / 6W variants.
View productQuality & Inspection
Beam options, IP construction and per-model documents confirmed against the exact configuration.
Inspection capabilitySend your elevation, get a project quote