How to Select a Wall Washer Beam Angle
Beam angle and setback are one decision. GDXC wall washers list 30°, 60°, 10×30° and 10×60°; choose against wall height, mounting plane and spill.
GDXC Lighting · Published November 27, 2026 · Updated November 29, 2026 · 5 min read
A wall washer beam angle is the spread of its emitted cone, chosen together with the setback from the wall. GDXC Lighting lists 30°, 60°, 10×30° and 10×60° on GD-WW3524 and GD-WW2418: symmetric 30°/60° for greater setback, asymmetric 10×30°/10×60° for close mounting where spill must stay low. A beam label is not a photometric file; the file follows the selected configuration.
Key points
- Beam option and mounting setback are a single decision; changing one without the other creates scallops or spill.
- The cited wall washers list four options: 30°, 60°, 10×30° and 10×60°.
- 10×30° and 10×60° are asymmetric: a narrow axis limits throw beyond the wall at short setback.
- GD-WW3524 is a 1002 mm body on a 995 mm profile; joint positions are drawn before fixture count.
Definition
A beam angle is the angular spread of the light emitted by a luminaire, measured between the directions where intensity falls to a stated fraction of the peak. In facade practice the label is a selection handle, not a full description: it says how wide the cone is, but not where the light lands on the wall. That position is set by the mounting setback — the distance from the fixture to the surface.
The two must be chosen together. A 60° bar mounted close to a wall throws a broad, uncontrolled field; the same 60° bar at a greater setback can cover a tall elevation evenly. A 10×30° bar mounted at the wrong distance produces a hard-edged band instead of a wash. GDXC Lighting lists four options on the cited wall washers, and the beam is fixed at the model level rather than adjusted on site.
The four listed options
The 2026 catalogue attaches the same four distributions to GD-WW3524 and GD-WW2418. The first two are symmetric; the last two are asymmetric, written as a narrow axis followed by a wide axis.
| Beam | Form | What it is used for | Body it is listed on |
|---|---|---|---|
| 30° | Symmetric, narrower | Greater setback, taller surfaces, more spill control | GD-WW3524, GD-WW2418 |
| 60° | Symmetric, wider | Shorter setback, more wall covered per bar | GD-WW3524, GD-WW2418 |
| 10×30° | Asymmetric | Close mounting where a narrow axis limits throw past the wall | GD-WW3524, GD-WW2418 |
| 10×60° | Asymmetric | Close mounting with wider spread along the wall | GD-WW3524, GD-WW2418 |
The optical distribution capability explains how these options are built and how photometric files are tied to a selected option. The wall washer definition covers the fixture class if the term itself is new.
Setback and beam are one decision
A specifier who picks a beam first and then finds a mounting position has the sequence backwards. Start with the elevation: how high the wall is, what surface texture it has, where a bracket can be fixed and how far that bracket sits from the wall. Only then compare beam options.
| Setback condition | Beam behaviour to expect | Option to compare first |
|---|---|---|
| Short, tight mounting plane | Beam hits the wall almost immediately; spill above and below is hard to control | 10×30° or 10×60° |
| Moderate setback with a tall wall | Coverage per bar increases, but hot spots appear if bars are spaced too far apart | 30° |
| Longer setback from a pedestal or opposite structure | Each bar covers more width; aiming and uniformity matter more than spill | 60° |
| Unknown mounting plane | No beam can be approved; record it as open | None — review first |
That last row is the honest answer for many inquiries. A reference photograph shows an effect, not a setback. A 2026 design-review inquiry supplied a 70 × 50 ft front elevation, and beam options were compared rather than assigned, because installation conditions were not confirmed. The custom project engineering page describes that boundary.
What the asymmetric options actually do
The 10×30° and 10×60° labels are the part most often misread. They describe two different planes. One axis is narrow and controls spill in the direction the bar points; the other is wide and controls coverage along the wall. Rotating the fixture changes which plane does which job.
That is why a label is not a photometric file. The photometric file for the selected model states the orientation of the distribution and the intensity at a stated distance. Without it, two bars with the same label can be mounted in different orientations and produce different walls. Request the file for the chosen option through the review; do not assume a file for 30° describes 10×30°.
GD-WW3524 is W35 × H24 × L1002 mm on a 995 mm profile, with a 4 mm silk-screened round-hole glass lens and rotating bracket. GD-WW2418 is W24 × H18 × L995 mm on a 985 mm profile with an IP67 glue-filled construction. The body, not the beam label, decides where the bracket can sit.
Spacing between bars
Beam selection cannot be separated from bar spacing. If the 1002 mm body of GD-WW3524 is treated as a nominal 1000 mm module, joint positions drift and gaps open up across the elevation. Draw the joint positions on the wall first, then count fixtures. Overlap between adjacent beams is what turns individual bars into a continuous field; underlap is what produces scallops.
Colour version interacts with this decision only indirectly. Single-colour, RGB and RGBW versions of the cited models share the four beam options, but the address plan changes with the version. See RGBW vs RGB architectural lighting for the control side.
Scope and limits
This article covers beam selection for surface-mounted linear wall washers on vertical architectural surfaces. It does not cover flood-light aiming, in-ground uplighting or submersible optics, and it does not provide a site illumination design sign-off or a certified glare value. The four beam labels are catalogue options for named models; photometric files and orientation are confirmed per configuration. GDXC applies a 3-year warranty across its outdoor fixture lines, but a warranty does not replace a beam review.
Selection sequence
- Read the elevation and record wall height, surface texture, setback and mounting plane.
- Compare the four listed beam options against that setback; keep them as one decision.
- For an asymmetric option, request the photometric file and confirm axis orientation.
- Draw joint positions using the actual body length — 1002 mm for GD-WW3524, 995 mm for GD-WW2418.
- Fix the model, then confirm colour version, DC24V loading and IP construction.
- Mark unknown installation conditions as open rather than assumed.
For the wider pre-order record, use the facade lighting buyer checklist.
Related reading
This article describes general outdoor lighting practice and catalogue figures. It is not a substitute for a configuration-specific review — beam option, IP construction, mounting conditions and per-model documents depend on the exact fixture.