Optical Distribution and Beam Control for LED Fixtures

Beam control for outdoor LED fixtures: 30°, 60°, 10×30° and 10×60° wall-washer options, 4 mm silk-screened glass and PC diffusers, photometric files per model.

Spherical photometric test equipment standing inside a dark measurement room used to record LED fixture light distribution
Photometric test rig for fixture light distribution.
Short answer

Optical distribution is the way a luminaire directs flux: beam angle, cutoff and uniformity at a stated distance. GDXC Lighting specifies wall washers at 30°, 60°, 10×30° and 10×60°, uses a 4 mm silk-screened round-hole glass lens on GD-WW3524 and a PC diffuser on GD-L2048PC. Photometric files follow the selected model.

When this process applies

This page covers beam selection and optical components in listed fixture families. It does not cover site illumination design sign-off or a certified glare value; beam files and lens construction are confirmed for the exact configuration.

Technical specifications

Wall-washer beam options30°, 60°, 10×30°, 10×60°
GD-WW3524 lens4 mm silk-screened round-hole glass
GD-L2048PC diffuserPC, aluminium + PC body
Compact flood array3×2W or 4×2W in a 65 × 65 × 55 mm body
In-ground aperturesØ62 mm (GD-IG225), Ø90 mm (GD-IG226)
Photometric filesSupplied per selected beam option on request

Where it is the right choice

  • Facade washing from a short setback with 10×30° or 10×60° options
  • Wider wall coverage using the 30° or 60° options
  • Continuous line effects with a PC-diffused linear bar
  • Aimed architectural flood and recessed ground-level effects

Where it is the wrong choice

Stating this explicitly matters more than a capability list: if your part falls into one of these categories, another process will cost you less.

  • Projects requiring a certified glare value without a per-model report
  • Fixtures whose beam must be changed on site — beam is a model option, not a field adjustment
  • Submersible optical systems, which are outside the listed outdoor families

Equipment

  • Spherical photometric test setup for distribution measurement
  • Beam option table covering 30°, 60°, 10×30° and 10×60°
  • 4 mm silk-screened round-hole glass for GD-WW3524
  • PC diffuser for GD-L2048PC
  • Ø62 mm and Ø90 mm aperture options in the in-ground series
Optical Distribution

Process questions

What is the difference between 30° and 10×30° beam options?

A 30° beam spreads light symmetrically; a 10×30° beam is asymmetric, narrowing in one axis to limit spill when a wall washer sits close to a wall. Both are listed for GD-WW3524 and GD-WW2418. The choice depends on setback, not on wall area alone.

Can photometric files be provided for a beam option?

Yes, per selected model and beam option on request. The listed options are 30°, 60°, 10×30° and 10×60° for the wall-washer family; a file for one option is not treated as a file for another.

Does a PC diffuser change beam angle?

It changes how the light leaves the bar. GD-L2048PC is an aluminium-plus-PC fixture with a 5055-48LED board; no single beam angle is assigned to it in the material available, so the diffuser and beam are confirmed together against the selected model.

Send your elevation, get a project quote

Send the facade drawing or fixture schedule with quantity and destination. Quotes are built per configuration and trade terms; no internal price list is published.

Chat on WhatsApp