Facade Lighting Buyer Checklist
A pre-order checklist for facade LED fixtures: elevation, setback, beam, IP construction, colour version, address plan and open items across 300+ projects.
GDXC Lighting · Published November 29, 2026 · 5 min read
A facade lighting buyer checklist is a pre-order record that fixes what is known and flags what is not before a fixture is specified. GDXC Lighting reviews facades against 20 wall-washer, 10 linear and 27 pixel models from 300+ projects, with a 3-year warranty on every line. The record covers elevation, setback, beam, IP construction, voltage, colour version and open items.
Key points
- The checklist separates figures that can be quoted from items that must stay open.
- Cite 300+ projects, a 3-year warranty and model-level catalogue figures; do not cite prices, certificate numbers or unpublished capacity.
- A 2026 design-review inquiry supplied a 70 × 50 ft front elevation and stayed anonymous.
- Beam, setback, enclosure and address plan are fixed together before an order is placed.
Definition
A facade lighting buyer checklist is a written pre-order record that lists the decisions already made and the items still open, so that a fixture schedule can be issued without filling gaps by assumption. It is not a quotation and not a design sign-off. Its value is that two people reading it arrive at the same fixture count, the same colour version and the same list of unanswered questions.
GDXC Lighting works across 11 product families and 98 catalogued models, including 20 wall washers, 10 linear bars, 29 floods, 12 in-ground fixtures and 27 pixel models. The company was founded in 2014, has delivered 300+ lighting engineering projects, and applies a 3-year warranty across every outdoor fixture line. Those are the figures that can be stated in a record; everything else is confirmed per model.
The checklist
| Item | What to record | Why it matters | GDXC figure to cite |
|---|---|---|---|
| Elevation | Dimensions and mounting plane | Sets fixture count and setback | Example review: 70 × 50 ft front elevation |
| Surface | Texture, colour, height | Decides wash versus grazing | 20 wall-washer models in the catalogue |
| Beam option | 30°, 60°, 10×30° or 10×60° | Beam and setback are one decision | Four options on GD-WW3524 and GD-WW2418 |
| Body and joints | Length and joint positions | Prevents gaps across a run | GD-WW3524: L1002 mm on a 995 mm profile |
| Enclosure | Listed IP construction | Describes the fixture body only | GD-WW3524 IP65; GD-WW2418 IP67 glue-filled |
| Voltage | DC24V or AC220V platform | Decides drivers and protection | GD-L2048PC 10W/12W/15W DC24V; compact flood AC220V |
| Colour version | Single-colour, RGB or RGBW | Sets address footprint | All three listed on GD-WW3524 and GD-L2048PC |
| Control | DMX512 address table | One table per version and layer | Multi-channel control for large projects |
| Field items | Connector, gland, drainage, joint | Not covered by the fixture enclosure | Specified separately per installation |
| Open items | Missing files, unverified conditions | Keeps the review honest | Marked as open, not assumed |
| Commercial terms | Model, configuration, MOQ and lead time | Confirmed after review | By model; no fixed figures published |
The custom project engineering page describes what is needed for a review and what the output contains. The wall washer definition is the starting point if the fixture class itself is still open.
Numbers you can quote, and numbers you cannot
Part of a buyer’s job is knowing which figures survive a review. Some are stable; others must not be written into a public schedule.
| Safe to cite in a record | Not published |
|---|---|
| 300+ lighting engineering projects | Employee count or factory floor area |
| 3-year warranty on every outdoor line | Internal prices or cost figures |
| Founded 2014; Shenzhen registered, Dongguan manufactured | Client names or project ownership claims |
| 11 families, 98 catalogued models by category | Certificate numbers of any kind |
| Model figures such as 18W/24W, DC24V, IP65 | Unverified compliance or test-claim wording |
| Catalogue lifetime figure, to verify per configuration | Treated as a tested lifetime or warranty |
The quality page and the downloads page are the right destinations for configuration material. GDXC products comply with CE requirements; no certificate number is published on this site. A catalogue lumen or lifetime statement is a listing to verify against the exact model, not a guarantee to copy into a specification.
Design review is not a completed project
In November 2026, an inquiry supplied a night-scene reference image and a 70 × 50 ft front elevation. The visible effect suggested a glowing roofline and window edges plus textured lower walls. Beam options of 30°, 60°, 10×30° and 10×60° were compared for a wall-washer candidate with a 24 × 30 × 995 mm body, a 985 mm profile, rotating or flat brackets and DC24V input at 12W/15W.
The review stopped there. Installation conditions, location and purchasing stage were not confirmed, and the photometric file, enclosure detail and mounting dimensions remained open. That is a design-review example, not a finished project, and no client is named. Keeping that line explicit is what makes the rest of the checklist trustworthy: a review records what is unknown rather than turning an anonymous inquiry into a reference.
Where the checklist meets the site
The fixture schedule is only one part of an outdoor installation. Beam and setback are covered in the beam-angle selection guide; enclosure boundaries in the IP ratings article; and the common failure interfaces in why outdoor LED fixtures fail. The facade application page shows how an elevation is read before a fixture is named.
Scope and limits
This checklist applies to fixture selection for outdoor architectural facades in the listed families. It does not provide structural or electrical sign-off, a fixed price, a guaranteed effect from a reference image, or a completed-project portfolio. MOQ and lead time are confirmed by model. Items absent from the catalogue extract are marked open rather than inferred.
How to use it
- Fill the elevation, surface and setback rows before naming a model.
- Fix beam, body length and joint positions as one block.
- Add enclosure, voltage, colour version and address plan for each fixture type.
- List field items — connectors, glands, drainage — as separate lines.
- Mark every unknown as open, then request the design review that closes it.
- Confirm commercial terms only after the configuration is fixed.