Outdoor LED Lighting for Commercial and Hospitality Sites
Entrance, canopy and terrace lighting from 29 flood models, 20 wall washers and 10 linear bars. Compact flood 65 × 65 × 55 mm at 3×2W or 4×2W.
Commercial and hospitality exterior lighting shapes entrances, canopies and outdoor seating areas with flood lights, wall washers and linear bars. GDXC Lighting catalogues 29 flood models, 20 wall-washer models and 10 linear models; the compact flood is 65 × 65 × 55 mm at 3×2W or 4×2W on AC220V, while facade bars run on DC24V with DMX512 options.
Scope of supply in this sector
This page covers fixture selection for commercial exteriors and hospitality grounds. It does not provide interior lighting design, sign-off for occupied spaces or named client references.
Requirements
| Flood models | 29 catalogue entries |
|---|---|
| Compact flood body | 65 × 65 × 55 mm |
| Compact LED array | 3×2W or 4×2W |
| Flood input | AC220V |
| Wall-washer models | 20 catalogue entries |
| Linear models | 10 catalogue entries |
| Control | DMX512 on listed facade bars |
Listed housing materials
- Cast aluminium flood body where specified
- Tempered glass front lens
- 6063 extruded aluminium wall-washer body
- PC diffuser on linear bars
- Sealed cable gland and connector parts
Applicable standards
- IEC 60598-1 — general luminaire requirements used as a design reference, not a company certification claim
- IEC 60529 IP code — enclosure protection only; drainage and joints are separate
- DMX512 control protocol — signal interface for listed DC24V facade bars
- Product details confirmed per model; no certificate number asserted here
Typical parts
- Compact flood, 65 × 65 × 55 mm, 3×2W or 4×2W, AC220V
- FL-BM / FL-FG project-series floods (wattage not published in current material)
- GD-WW3524 wall washer, 18W/24W, DC24V
- GD-L2048PC linear bar, 10W/12W/15W, DC24V
- Mounting brackets and sealed connectors
Quality risks specific to this sector
These are the failure modes we see most often in this industry. They are listed because knowing them before design review is cheaper than discovering them at first article.
- AC220V compact floods at 3×2W or 4×2W and DC24V facade bars need separate circuits; a single control zone cannot drive both without a reviewed interface.
- A 65 × 65 × 55 mm flood cannot be sized by body size alone for an entrance throw; fixture count follows throw distance and aim angle.
- Outdoor seating areas add washdown and connector exposure: an IP65 body does not cover a poorly terminated cable joint.
Compliance and capability questions
Which fixtures suit a hotel entrance or canopy?
Aimed floods and facade bars are usually reviewed together. The catalogue lists 29 flood models, including a compact 65 × 65 × 55 mm body at 3×2W or 4×2W on AC220V, and 20 wall-washer models on DC24V; throw distance and mounting plane decide the split.
Can floods and wall washers share a driver?
No. The compact flood is AC220V at 3×2W or 4×2W, while listed wall washers and linear bars are DC24V with DMX512 options. Drivers and protection devices are planned as separate circuits.
How are enclosure ratings specified for these fixtures?
Catalogue ratings such as IP65 and IP67 describe the housing construction only. Field joints and cable glands are specified for the installation; this site publishes no certificate numbers.
Industries we also supply
Building Facade
Building facade lighting uses exterior fixtures to reveal elevation texture, edges and depth after dark. GDXC Lighting reviews facades against 20 wall-washer models, 10 linear models and 27 pixel models; a 2026 inquiry supplied a 70 × 50 ft front elevation.
View sectorBridge & Infrastructure
Bridge and infrastructure lighting uses linear bars and aimed fixtures to mark railings, edges and structural lines for night visibility. GDXC Lighting lists 10 linear models and 29 flood models; GD-L2048PC is W20 × H48 × L1000 mm at 10W/12W/15W on DC24V, while compact floods are 65 × 65 × 55 mm at 3×2W or 4×2W on AC220V..
View sectorCultural Tourism & Nightscape
Cultural tourism and nightscape lighting builds patterned scenes across facades, plazas and landscape features with point sources and linear bars. GDXC Lighting lists 27 GD-P / GD-PM pixel models and 10 linear models; the catalogue describes 160 mm pixel pitch and 30 pixels per string, both treated as descriptive figures.
View sectorSend your elevation, get a project quote
Send the facade drawing or fixture schedule with quantity and destination. Quotes are built per configuration and trade terms; no internal price list is published.