LED Lighting for Bridges and Infrastructure

Linear bars and floods for bridge railings and infrastructure edges: 10 linear and 29 flood models, GD-L2048PC at 10W/12W/15W DC24V.

Linear LED fixtures and their mounting rail laid out along a railing section for a lighting test
Linear fixtures and mounting rail on a railing section.
Short answer

Bridge and infrastructure lighting uses linear bars and aimed fixtures to mark railings, edges and structural lines for night visibility. GDXC Lighting lists 10 linear models and 29 flood models; GD-L2048PC is W20 × H48 × L1000 mm at 10W/12W/15W on DC24V, while compact floods are 65 × 65 × 55 mm at 3×2W or 4×2W on AC220V.

Scope of supply in this sector

This page covers fixture selection for railings, edges and structural accents. It does not provide structural load certification or civil works design; mounting and load class are confirmed by the responsible engineer.

Requirements

Linear models10 catalogue entries
GD-L2048PC bodyW20 × H48 × L1000 mm
GD-L2048PC power10W / 12W / 15W
Linear inputDC24V
Flood models29 catalogue entries
Compact flood65 × 65 × 55 mm, 3×2W or 4×2W, AC220V
ControlDMX512 on listed linear models

Listed housing materials

  • Aluminium plus PC body on GD-L2048PC
  • 6063 extruded aluminium profile where specified
  • Cast aluminium flood body where specified
  • Tempered glass front lens
  • Sealed connectors and mounting rail hardware

Applicable standards

  • IEC 60598-1 — general luminaire requirements used as a design reference, not a company certification claim
  • IEC 60598-2 series — applicable luminaire part reviewed per installation type
  • IEC 60529 IP code — enclosure protection only; joints and load class are separate
  • DMX512 control protocol — signal interface for listed linear models

Typical parts

  • GD-L2048PC linear bar, W20 × H48 × L1000 mm
  • Compact flood, 65 × 65 × 55 mm, 3×2W or 4×2W
  • FL-BM / FL-FG project-series floods (wattage not published in current material)
  • Railing mounting rail and bracket set
  • Sealed cable connectors at each junction

Quality risks specific to this sector

These are the failure modes we see most often in this industry. They are listed because knowing them before design review is cheaper than discovering them at first article.

  • A 1000 mm linear bar on a DC24V railing run must be loaded as a whole run: driver sizing based on one bar leaves the last fixtures under-supplied.
  • AC220V compact floods at 3×2W or 4×2W and DC24V linear bars cannot share one driver zone; mixing them creates a control and protection mismatch.
  • An IP-rated body does not cover a railing cable joint exposed to movement and weather; the joint rating is specified separately from the fixture.
Bridge & Infrastructure

Compliance and capability questions

Which fixtures are used for bridge railing lighting?

Railing lines are usually built from linear bars such as GD-L2048PC, a W20 × H48 × L1000 mm DC24V fixture at 10W/12W/15W. The 10 catalogue linear models are reviewed against the mounting rail and run length; flood models are a separate, aimed layer.

Can linear bars and floods share one control zone?

Not without a reviewed interface. The listed linear bar is DC24V with DMX512 control, while the compact flood is an AC220V fixture at 3×2W or 4×2W. Driver platforms and protection devices are designed separately.

Do you certify fixtures for bridge structures?

No structural or load certification is claimed here. Standards such as IEC 60598-1 and the IP code are design references; mounting, vibration exposure and load class are confirmed by the engineer responsible for the structure.

Send your elevation, get a project quote

Send the facade drawing or fixture schedule with quantity and destination. Quotes are built per configuration and trade terms; no internal price list is published.

Chat on WhatsApp